How do you perform a fire extinguisher inspection?
Fire Extinguisher Inspection Checklist
- Confirm the extinguisher is visible, unobstructed, and in its designated location.
- Verify the locking pin is intact and the tamper seal is unbroken.
- Confirm the pressure gauge or indicator is in the operable range or position, and lift the extinguisher to ensure it is still full.
What is the standard for inspection testing and maintenance of portable fire extinguishers?
§6151. Portable Fire Extinguishers.
Type of Extinguishers | Test Interval (years) |
---|---|
Soda acid (soldered brass shells) (until 1/1/82) | [FN1] |
Soda acid (stainless steel shell) | 5 |
Cartridge operated water and/or antifreeze | 5 |
Stored pressure water and/or antifreeze | 5 |
How do you take care of and maintain a fire extinguisher?
You must ensure that:
- The extinguisher is not blocked by equipment, coats or other objects that could interfere with access in an emergency.
- The pressure is at the recommended level.
- The nozzle or other parts are not hindered in any way.
- The pin and tamper seal (if it has one) are intact.
How do you inspect a fire extinguisher OSHA?
Look for obvious signs of physical damage, such as corrosion, leakage, or dents. Check the pressure gauge to make sure the indicator is in the operating range. Make sure the pull-pin is not missing and the pull pin seal is intact. Verify the date of the last professional inspection.
Can I service my own fire extinguishers?
Basic Service There is no guidance set out in the Fire Safety Order 2005, besides that it needs to be conducted by a “competent person”. However, it’s highly recommended that this kind of servicing be conducted by someone who is third party accredited.
Who is responsible for the inspection testing and maintenance of fire extinguishers to ensure that they will be in working order when needed?
The employer
Inspection, maintenance and testing. The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace. Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.
How often must maintenance be performed on an extinguisher?
once per year
Employers need to perform a full maintenance check on their workplace’s portable fire extinguishers once per year, according to OSHA 29 CFR 1910.157(e)(3). “Maintenance” means a thorough examination and repair, as needed, of all your facility’s portable fire extinguishers, as covered in NFPA 10(98), Sec.
How often do fire extinguishers need to be inspected OSHA?
Inspection, maintenance and testing Visually inspect portable extinguishers or hoses monthly. [29 CFR 1910.157(e)(2)] Perform an annual maintenance check on portable fire extinguishers.
How often fire extinguisher should be serviced?
How often should I be servicing my fire extinguishers?
Type of extinguisher | Basic service | Extended service |
---|---|---|
Water-based | 12-monthly [every year] | Every 5 years |
Powder | 12-monthly [every year] | Every 5 years |
Powder-primary sealed | 12-monthly [every year] | Every 10 years |
Clean agent | 12-monthly [every year] | – |
What type of test normally performs on an extinguisher?
Hydrostatic testing
Hydrostatic testing is a way to test the fire extinguisher tank for leaks and overall strength. The National Fire Protection Association (NFPA) publishes rules for how often portable fire extinguishers must be tested.
How often fire extinguishers should be inspected?
every 12 months
You must have your fire extinguishers serviced, every 12 months – this is what’s known as a “basic service” and needs to be done in accordance with BS 5036-6. This service is best done by a third party accredited fire extinguisher technician, with the correct tools, training and experience.
Do you need a qualification to service fire extinguishers?
This usually consists of an annual basic service plus an extended service / overhaul every five years (with the exception of CO2 extinguishers, which have a 10 year cycle). Simply put, there’s no necessary qualification for a fire extinguisher technician to have passed before they can begin work.
How do I check if a fire extinguisher is regularly inspected?
Note if an inspection tag is available. The tag should indicate that a fire extinguisher is regularly inspected. Once done with the inspection, summarize observations/ action plan. Make sure to sign off on the fire extinguisher inspection tag (if available) with your name/signature and date of inspection.
What are the maintenance procedures for a fire extinguisher?
Maintenance procedures must include the procedures detailed in the manufacturer’s service manual and a thorough examination of the basic elements of the fire extinguisher, including the following: 1 Mechanical parts of all fire extinguishers 2 Extinguishing agent 3 Expelling means 4 Physical condition More
How do you test a hydrostatic fire extinguisher?
A hydrostatic test always begins with an internal and external examination of the extinguisher as described in the maintenance section. The extinguisher then has many of its components removed so it is stripped down to pretty much just the shell and hose and is filled with water at a certain pressure for a certain time.
Why is portable fire extinguisher inspection so important?
Portable fire extinguisher inspection is extremely important for the protection of businesses and homes — especially since OSHA and Fire Codes require specific procedures when it comes to fire extinguishers in the workplace. Read on to discover the best fire extinguisher testing schedule for optimal safety and compliance.