What is Bil basic insulation level?
The basic insulation level or BIL of an electrical equipment determines the principle dielectric qualities of the apparatus and is expressed for impulse tested apparatus by peak value of the 1/50 microsecond full wave withstand voltage.
How is a transformer liquid insulation level determined?
The ‘insulation level’ of such designs is determined by a combination of the specified clearances and the ability to withstand, for one minute, the prescribed value of test voltage. This is accepted as equivalent to the power frequency and impulse voltage test philosophy.
What is a transformer BIL rating?
BIL rating specifies the minimum voltage that transformer can withstand under this condition. The method of testing of the transformer for BIL has been defined and set by IEEE and ANSI standards. The wave shape has been also defined which is commonly known as 1.2/50 μs voltage wave.
What does Bil mean on a transformer?
basic insulation level
There are two basic classifications of insulation strength: basic insulation level (BIL) or lightning-impulse withstand voltage, and power-frequency withstand voltage (often called “hipot” voltage).
What is the typical current rating for testing power transformer?
Typical burden ratings for IEC CTs are 1.5 VA, 3 VA, 5 VA, 10 VA, 15 VA, 20 VA, 30 VA, 45 VA and 60 VA. ANSI/IEEE burden ratings are B-0.1, B-0.2, B-0.5, B-1.0, B-2.0 and B-4.0. This means a CT with a burden rating of B-0.2 will maintain its stated accuracy with up to 0.2 Ω on the secondary circuit.
What is Bil testing?
BIL is an abbreviation for Basic Insulation Level. Insulation levels in electrical equipment are characterized by the withstand voltages used during the impulse test. This test is done with the initial transformer design to validate the integrity of the insulation and its high frequency surge withstand capability.
What is the maximum temperature limit of Class A insulation?
What is meant by “Class” in insulation?
Insulation Rating | Insulation Class | Maximum Winding Temperature |
---|---|---|
Class 105 | A | 105 degree C |
Class 150 or 130 | B | 150 degree C |
Class 180 | F | 180 degree C |
Class 200 | N | 200 degree C |
What is rated insulation voltage?
The highest operating voltage that will not cause a dielectric strength failure. The rated insulation voltage is used as a parameter for dielectric strength tests and for the creepage distance. The rated insulation voltage must always be higher than the rated operating voltage (Ue).
What is Bil (Basic Insulation Level of electrical equipment)?
This minimum voltage rating is defined as BIL or basic insulation level of electrical equipment. It is needless to say, that the voltage withstanding capacity of all equipments of an electrical substation or an electrical transmission system must be decided as per its operating system voltage.
How to select base insulation level for substation?
The selection of this base insulation level for lines depends on the atmospheric conditions, the lightning activity,presence of insul The basic Insulation Coordination of Substation is often determined by giving a margin of 25-30\% to the protective level of surge arrester and selecting the next nearest standard BIL.
What type of insulators are used in electrical bushings?
For outdoor use, either porcelain or composite insulators are used. These bushings provide significant technical advantages such as being fully dry and pressure-free, feature a high-temperature class, normally stable and low partial discharge levels, low dielectric losses, fire-resistant, and outstanding mechanical properties.
What causes a bushing breakdown in a transformer?
A bushing breakdown can occur even when a transformer is operated within its maximum specified limits. This happens if the deterioration of the bushing’s internal insulation system was not detected in time to act.